What does RF mean on Honeywell Zone board?
Radio Frequency (RF) Receivers provides 24 Vac control of heating and cooling systems.
What does the Honeywell HZ322 do?
HZ322/U. The TrueZONE® HZ322 Panel is for conventional and heat pump applications up to 3 zones (2H, 2C) at 24 Volts. It features robust push terminals, common-sense LEDs, variable-speed fan control, and leaves a smaller environmental footprint.
What does purge mean on Honeywell HZ322?
“Purging” is the process of clearing an air conditioner’s (AC’s) unit’s internal lines and hoses. This is frequently done before recharging freon but. many newer model AC units, such as Honeywell units, purge the system on startup.
What is RF enabled Honeywell?
RF supervision on a Honeywell VISTA P-Series System works by requiring any programmed wireless sensors to check in at least once every 12 hours. By adding a wireless receiver, you will be able to use wireless 345 MHz sensors from the Honeywell 5800 Series.
What does a dats sensor do?
The C7835A1009 Discharge Air Temperature Sensor (DATS) is a duct-mounted temperature probe that provides capacity control of heating and cooling equipment. The DATS also compares the discharge air temperature to the room temperature and, if out of tolerance, a heating or cooling alert is issued.
What is purge override?
When the zone panel cover is off, the EMERGENCY HEAT/PURGE OVERRIDE button is visible. When the panel is in Purge (at startup or after a call for heat/cool), pressing this but- ton stops the Purge, which saves time during installation or troubleshooting.
Where to mount the Honeywell hz322 truezone panel?
69-2199—052 M28029 Mount the HZ322 TrueZONE panel near the HVAC equipment; locate it on a wall, stud, roof truss, or cold- air return. NOTE:The HZ322 TrueZONE panel can be mounted in any orientation; level it for appearance only.
How to set Honeywell truezone to wireless mode?
The TrueZONE must be configured for wireless devices to select Wireless mode. BACK ADJUST SETTING NEXT M28194 Press Next to add devices. While the display alternates the Press Connect and Exit screens, push the Connect button (s) on the wire- less device (s).
What are the controls on the truezone hz322 heat pump?
The HZ322 TrueZONE®panel controls: • Conventional gas, oil, or electric forced-air systems up to 2 stages heat and cool; • Heat pump systems with single stage compressor and auxiliary heat, and two stage heat pumps with no auxiliary heat; and two stage heat pumps with no auxiliary heat;
How to connect truezone thermostat to zone panel?
Connect thermostat to zone panel. To connect wire to the panel, strip approximately 1/4 in. of insulation and push wire into terminal. To release wire, press the button on top of the terminal. In retrofit applications, trim end of wire if not straight. 3 Install dampers using instructions provided with dampers.