How does a manual pull station work?
Pull stations send a signal to the control panel, and if the fire alarm is monitored, the control panel then usually sends a message to a company’s monitoring service, which transmits that message to first responders. In some cases, a signal is transmitted directly to a fire department.
Where are manual pull stations required?
NFPA 72 requires that manual pull stations be installed within 60 inches of the exit doorway of each exit, mounted between 42 inches and 48 inches to the center of the handle, and, among other things, be red in color. Below we have an picture of a typical manual pull station.
When should you activate a fire alarm manual pull station?
Upon detecting a potentially hazardous situation, use the fire alarm pull station promptly to minimize the loss of life and property due to fire. Once the alarm has activated, contact emergency responders by calling 911 from a safe location.
What is the purpose of a manual alarm station?
Manual call points They are used to allow building occupants to signal that a fire or other emergency exists within the building. When activated they will raise a plastic flag out of the top to tell which alarm was activated.
Who pulls fire alarms?
The only one that gets to the fire department is the fire alarm. The alarm monitoring company calls the building owner first. The company will assume an emergency and contact the fire department if they can’t get in touch with the building owner. The property owner is responsible for the fire department dispatch.
When should you pull a fire alarm?
If you smell or see smoke or fire, alert others in the nearby area, activate the fire alarm by pulling a fire alarm pull station and evacuate. WHEN A FIRE ALARM IS ACTIVATED EVACUATION IS MANDATORY!
Do fire alarm pull stations have to be red?
The location of your fire alarm pull stations will depend on the design and occupancy of your building. Additionally, a fire alarm pull station needs to be red and in a location that is completely unobstructed from obstacles. This way, anyone can access the pull station in an emergency.
How many manual pull stations are required?
one manual fire pull station
The National Fire Protection Association (NFPA) 101 Life Safety Code requires at least one manual fire pull station in each building. The code states that a building should not entrust life safety to only one safeguard, and directs that additional safeguards be implemented.
What happens if a red manual call point is activated?
MCP – Manual Call Point is the small red box with the glass panel and button. Breaking the glass and pushing the button will activate the Fire Alarm. Mobility Impaired Person – A person with physical, mental or sensory impairment, either temporary or permanent, who requires assistance during emergency evacuations.
When should I pull my fire alarm?
What is manual fire alarm system?
Manual Fire Alarm System A building fire emergency notification system consisting minimally of audible and visual alarm notification appliances (i.e., horns and strobes) installed within all common-use areas of a building and manual alarm stations (i.e., pull stations) installed at every exit from every level.
What is a manual alarm?
Home / Fire Alarms / Manual Call Points. A manual call point is a device which enables personnel to raise an alarm in the event of a fire incident by pressing a frangible element to activate the alarm system.
Where are fire alarm pull stations located?
A fire alarm pull station is usually hung at or near eye-level in a hallway or on the wall of a common area. Ideally, it is located in a section of the facility that is unobstructed by other items and easily accessible.
What is the standard height of a fire alarm pull station?
As to mounting height of manual fire alarm pull stations NFPA 72 National Fire Alarm and Signal Code 2016 ED. Section 17.14.5 states The operable part of a manual actuated alarm initiating device shall not be less than 42″ ( 1.07 m ) and not more than 48″ ( 1.22 m ) from the finished floor.
What is emergency pull station?
The CT-155 Wireless Emergency Pull Cord Station is a compact wall-mount transmitter that is capable of sending text message directly to pocket pagers, alphanumeric LED message boards and central monitoring stations.
What is an alarm pull station?
A fire alarm pull station is a wall-mounted device that usually has a T-shaped lever in the center. This station is connected to an alarm system that sounds when the lever is depressed. In some cases, pulling this lever will cause a light to flash as well. The alarm and flashing lights usually alert building…