What should be the size of plinth beam?
The minimum size of the RCC plinth beam should not be less than 9 “x 9” (225 mm x 225 mm), as a general rule of thumb. The plinth beam size for a 1-story building is 9 “x 9” (225 mm x 225) mm) and is 9″x 12″ (225 mm x 300 mm) plinth beam sizes are used for 2 story (G + 1), 3 story (G + 2) and 4 story (G + 3) houses.
What is the minimum height of plinth beam?
Minimum height of plinth beam is kept about 1 feet (300mm) high from ground level for residential and commercial building.
How do you calculate load on a plinth beam?
Load Calculation of Beam
- 300 mm x 450 mm excluding slab thickness.
- Concrete Volume = 0.3 x 0.60 x 1 =0.138m³
- Concrete weight = 0.138 x 2400 = 333 kg.
- Steel weight (2%) in Concrete = = 0.138 x 0.02 x 7850 = 22 kg.
- Total Column weight= 333 + 22 = 355 kg/m = 3.5 KN/m.
What is thickness of plinth beam?
Plinth beam size for 2 storey (G+1) house:- for 2 storey (G+1) house or in simple 2 floor building, general thumb rule, using standard 9″ thick walls, size of Plinth beam should be 9”x 12” (230mm x 300mm) provided with 2 nos of 12mm bar at top, 2 nos of 12mm bar at bottom and 1 extra bar of 10mm is provided in mid span …
What is the depth of plinth beam?
Depth of Plinth Beam: The depth of the plinth beam should not be less than 20cm.
How much should be the plinth of a house?
The plinth therefore would be Height of filling + minimum 450 or 600 to 900 mm. Plinth height includes plinth wall & plinth beam depending on the height of plinth and filled with compacted soil.
How much should be the plinth of a house in CM?
The plinth or any part of a building or outhouse shall be so located with respect to average road level from site so that adequate drainage of the site is assured but at a not height less than 45 cm. These shall be raised at least 15 cm. above the surrounding ground level and shall satisfactorily drained. Sl.
How do you calculate concrete for a plinth beam?
Calculation of volume of concrete for the column:
- Volume of Concrete = 0.6×0.4×3= 0.72m3
- Volume of Circular column = πr2 x 3 = 3.14 x 0.252 x3 = 0.58m3
- Volume of concrete = 1.2x1x0.1 = 0.12m3 Total volume of concrete required for footing= 0.32+0.12=0.44m3
How do you design a plinth beam?
In general practice, the mark-up width of the plinth beam is kept equal to half the width of the foundation. For example; if the foundation is approximately 16” wide then the mark-up width of the plinth beam must be equal to 8”. The mark-up width of the plinth beam must be aligned from the outer edge of the foundation.
What is the standard size of plinth?
minimum size of an RCC plinth beam should not be less than 9”x 9” (225mm x 225mm), according to general Thumb Rule, for 1 storey building size of plinth beam is 9”x 9” (225mm x 225mm) and 9”x 12” (225mm x 300mm) plinth beam size is used for 2 storey (G+1),3 storey (G+2) and 4 storey (G+3) house.