Error description An S213 abend or other OPEN failure may occur when message explanations are generated at the end of a Tivoli Advanced Catalog Management job step. This is replaced with a warning message that the libraries could not be opened. A similar message will be issued if the MSGLIB cannot be allocated.

What is abend code in JCL?

The abend reason code is the value of the RDJFCB macro return code. Ensure the JCL contains a SYSCOM DD statement.

What is a S213?

This so called Prescribed information or Section 213 Notice is required to inform the tenant of how the deposit is being held and how they get it back at the end of the tenancy.

How do I resolve my soc7 abend?

go to spool and take the last four bytes of offset. open the compiler listing and find those 4 bytes in the compiler listing. you can find the position, where S0C7 occured. In this way , we can find the position where S0C7 error got generated.

What is abend error in mainframe?

An error occurred in opening a data set because of conflicting or unspecified data set attributes. Possible causes: There was a conflict between the program, the JCL, and the data set label DCB information required. Directory space was not allocated for a partitioned data set.

What is abnormal termination JCL?

DELETE. Indicates that the data set’s space on the volume is to be released if this step terminates abnormally. The space can be used for other data sets; the data set is not erased from the space.

What is an oc7?

The error – ‘System Completion Code=0C7’ or called S0C7 is usually data related. In a given record there is unexpected binary characters in address fields. Once this record is removed, the error goes away. To narrow down the file to find this record, the file can be split in half to find the record.

Why do I have an ABEND code S001?

JCL SYSTEM & USER ABEND CODES S001 An I/O error condition was encountered during BDAM, BISAM, BPAM, BSAM, QISAM, or QSAM processing Possible causes: An attempt was made to read after end-of-file. An attempt to open an open file. There was a conflict between the program, the JCL DCB, and the data set DCB information.

What did Abend s213-08 open macro for password protected dataset?

S213-08 An OPEN macro was issued for a password protected dataset but the system was unable to locate the password dataset. S213-0C An I/O error occurred reading a FORMAT 1 DSCB for a direct or indexed sequential dataset, or the FORMAT 1 DSCB could not be found on the volume specified by the DD statement.

Is there a storage limit for S000 u0012?

Anything higher then 23 can cause the S000 U0012 abend. The default value of LIMIT (20,P) (yielding a 1M maximum storage request size for below the line storage) should be adequate for most installations.

What is the reason for the error code S012?

S012 A program incorrectly issued a TIMEUSED macro. A reason code in register 15 explains the error: reason code 4 – The program issued TIMEUSED with LINKAGE=SYSTEM, but the program was not in task control block (TCB) mode.