How do I fix the ribbon fault on my Datamax printer?
To eliminate a ‘Ribbon Fault’ error message on a Datamax-Oneil I Class Mark II printer when initially receiving the printer and utilizing Direct Thermal labels….Trough the Printer Menu :
- ‘Menu’ > ‘Media Settings’ > ‘Media Type’
- Change ‘Thermal Transfer’ to ‘Direct Thermal’
- ‘Enter’ > ‘Exit’ > ‘Save Changes’ > ‘Yes’.
How do I calibrate a Datamax I Class printer?
Quick Calibration > while the labels are installed press and hold the ‘Feed’ button for 10 seconds then release and at that point the printer should state “Calibration Complete” you might see the word pause on the printer display at that point press the ‘Pause’ button then the printer should state ready on its display.
How do I reset my Datamax label printer?
Factory Reset
- In the Desktop program RevolutionEHR Printing, access Utilities > Printer Diagnostics.
- Select the appropriate Datamax printer.
- Within the menu for Printer Diagnostics, access Printer Settings > Datamax > Restore Factory Defaults.
- Click ‘Send.
- Follow the instructions for Media Calibration.
How do I reset my Datamax class?
To Factory Default the Datamax fixed industrial printers listed above: using their front-panel menu…
- Turn the printer off.
- Wait 30 seconds.
- While holding in all three front-panel buttons – ‘PAUSE’ + ‘FEED’ + ‘CANCEL’ – just under the LCD and turn on the printer.
How do I remove the ribbon from my Datamax printer?
The ribbon is installed on a collapsable rewind hub. Pull/remove the hub, as it is able to come out 10 to 15mm. The hub will collapse and the ribbon will come off.
How do I reset my Honeywell M Mark 2?
To select revert the Network Settings to their defaults, without affecting the printer’s other settings…
- Select ‘Menu’ > ‘Communications’
- For H- and M-Class printers, select ‘NIC Adapter’
- Select ‘Quick Setup’
- Select “Set Factory Defaults” and then press the ‘Enter’ soft-key.
- The printer should Warm Boot.
What is the difference between direct thermal and thermal transfer?
Direct thermal printing uses chemically treated, heat-sensitive media that blackens when it passes under the thermal printhead, while thermal transfer printing uses a heated ribbon to produce durable, long-lasting images on a wide variety of materials.
What is thermal ribbon?
A thermal transfer ribbon is a thin film that is wound on a roll that has a special black coating on one side. This coating is usually made from a wax or resin formulation. During thermal transfer printing, the ribbon is run between the label and the printhead, with the coated side of the ribbon facing the label.
Does thermal transfer require ribbon?
Thermal transfer (TT) printing requires a ribbon to print. The ribbon acts as a buffer between the print head and the label material. As the thermal ribbon passes over the heated print head, it melts onto the label.
What is Sato ribbon?
Developed as a result of a high level of expertise, SATO ribbons are low power and offer high resolution printing for a wide variety of applications. The SATO ribbon range complies with GHS regulations and can be used for food packaging, where approved direct food contact marking and coding is required.
How to eliminate a ribbon fault error on the Datamax?
Resolution. To eliminate a ‘Ribbon Fault’ error message on a Datamax-Oneil I Class Mark II printer when initially receiving the printer and utilizing Direct Thermal labels. ‘Menu’ > ‘Media Settings’ > ‘Media Type’. Change ‘Thermal Transfer’ to ‘Direct Thermal’. ‘Enter’ > ‘Exit’ > ‘Save Changes’ > ‘Yes’.
What to do if you have a ribbon fault?
If using direct thermal stock change the Media Type setting to Direct Thermal; otherwise ensure that ribbon is installed. Press the FEED Key to clear the fault — if the fault does not clear check the Ribbon Hubs for free movement.
What to do when your ribbon is not working?
Also, ensure that the ribbon core fits snugly onto the supply hug, and that the ribbon is not slipping or stalling as labels print. If no binding, slipping, or stalling is apparent press and hold the FEED Key until at least three labels have been output. If the fault does not clear, call for service.