7 Steps to Reprocess Your Flexible Endoscope

  1. Pre-Clean Your Scope. Reprocessing begins in the procedure room.
  2. Perform a Leak-Test.
  3. Manually Brush & Flush.
  4. Rinse & Dry.
  5. Disinfect.
  6. Flush with Alcohol.
  7. Store & Don’t Forget to Document!

What are the six steps required to reprocess flexible endoscopes?

Essential Steps for Flexible Endoscope Reprocessing

  • Pre-Cleaning. a. Pre-Clean flexible endoscopes and reusable accessories by following the device manufacturer’s instructions for use (IFU).
  • Leak-Testing. a.
  • Manual Cleaning. a.
  • Visual Inspection. a.
  • Disinfection or Sterilization. a.
  • Storage. a.
  • Documentation. a.

What chemical method would be used to sterilize a flexible endoscope?

Peracetic acid removes surface contaminants (primarily protein) on endoscopic tubing. An automated machine using peracetic acid to sterilize medical, surgical, and dental instruments chemically (e.g., endoscopes, arthroscopes) was introduced in 1988.

How do you clean a flexible endoscope?

Clean the external surface of the endoscope with detergent using soft cloths, sponges, or brushes. Flush and brush all accessible channels to remove debris and other contaminants. Hard-to-clean areas or accessories should be cleaned with an ultrasonic cleaner.

What is the process of reprocessing?

Reprocessing is a multistep process that includes cleaning, inspection and assembly, functional testing (if applicable), disinfection (if applicable), packaging and labelling, sterilization (if applicable) and storage.

What is endoscopy reprocessing?

The purpose of endoscope reprocessing is to provide a reusable endoscope that is safe for patient use. This is achieved using current, evidence-based, best-practice in endoscope reprocessing. This procedure applies to staff who use or reprocess endoscopes.

What is the most important step in processing flexible endoscopes?

Manual cleaning is the most important step in reprocessing flexible endoscopes. The manufacturer’s instructions should be followed in the selection and use of endoscope cleaning brushes. Either a single-use or a clean brush should be used for each endoscope reprocessed.

How do you sterilize endoscopes?

Adequate disinfection and decontamination of GI endoscopes involves manual cleaning and automatic high-level disinfection (HLD) followed by 75% ethanol rinsing and then hanging for endoscope drying before storage.

When should endoscope pre cleaning begin?

60-minutes
Manual cleaning must begin within 60-minutes of precleaning or else the endoscope must undergo prolonged soaking. 60 min.

What are the three 3 reprocessing procedures for equipment?

Are endoscopes reused?

Reusable medical devices are devices that health care providers can reprocess and reuse on multiple patients. Examples of reusable medical devices include surgical forceps, endoscopes and stethoscopes.

Are endoscopes always sterile?

Endoscopy equipment should always be cleaned, disinfected, and sterilized for infection control.

Can a flexible endoscope be used in a healthcare facility?

Healthcare facilities can use these sample documents to incorporate the Essential Elements of Flexible Endoscope Reprocessing into their reprocessing program. These tools can be modified to meet your facility’s specific needs.

How to become a flexible endoscope reprocessor ( GI scope ) certification?

Completion of an Endoscopy Technician course with a minimum of 8 hours and a grade of 70 or higher (provide copy of certificate/grade from your instructor) AND 6 months experience processing flexible endoscopes (provide verification signed by your Manager on your exam application) …OR

Who is involved in the reprocessing of endoscopes?

All personnel involved in the reprocessing of endoscopes, including the supervisors and managers of reprocessing personnel, receive ongoing education, training and assessment of competency as outlined in the Education, Training and Competencies section. i.

When to transport endoscopes to the processing room?

Contaminatedflexible endoscopes and accessories should be transported tothe endoscopy processing room as soon as possible after use. Endoscopes and accessories should be kept wet or damp but not submergedin liquid during transport.